Advanced solar control and thermal insulation glass that is a perfect choice for sustainable buildings in single glazing application.
SGG Evo is an energy efficient glass that offers high performance across all seasons. It is a cutting-edge product that offers dual advantages of solar protection and thermal insulation in both Single and Double Glazing applications. SGG Evo has very low internal reflection, higher light transmission, a low solar factor and U-Value. It is available in neutral, green and blue and bronze shades.
Thickness Available in 4mm, 5mm, 6mm, 8mm* (available on special request),10mm and 12mm (in neutral shades).
Product | Visual Comfort | Thermal Comfort | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
Selectivity | Tuv(%) | UV cutdown(%) | |||
|
|
|
|
|
|
|
0.97 | 9 | 91 | |||
|
|
|
|
|
|
|
0.92 | 3 | 97 | |||
|
18 | 14 | 9 | 0.23 | 0.27 | 3.8 | 0.78 | 3 | 97 | |||
|
50 | 13 | 11 | 0.5 | 0.58 | 5 | 1 | 22 | 78 | |||
|
41 | 10 | 11 | 0.39 | 0.45 | 5 | 1.05 | 9 | 91 | |||
|
32 | 8 | 10 | 0.36 | 0.42 | 5 | 0.89 | 8 | 92 | |||
|
34 | 23 | 8 | 0.34 | 0.39 | 3.9 | 1 | 10 | 90 | |||
|
28 | 17 | 7 | 0.27 | 0.32 | 3.9 | 1.04 | 4 | 96 | |||
|
21 | 12 | 7 | 0.26 | 0.29 | 3.9 | 0.81 | 4 | 96 |
Product | Visual Comfort | Thermal Comfort | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
External Reflection (%) | Internal Reflection (%) | Solar Factor (SF/SHGC) |
co-efficient (SC) |
U-value (W/m2K) | Selectivity | Tuv (%) | UV cutdown(%) | |||
|
25 | 29 | 15 | 0.23 | 0.27 | 2 | 1.09 | 7 | 93 | |||
|
21 | 21 | 15 | 0.18 | 0.21 | 2 | 1.17 | 3 | 97 | |||
|
16 | 14 | 15 | 0.16 | 0.19 | 2 | 1.00 | 3 | 97 | |||
|
45 | 15 | 17 | 0.42 | 0.48 | 2.6 | 1.07 | 17 | 83 | |||
|
37 | 12 | 17 | 0.3 | 0.34 | 2.6 | 1.23 | 7 | 93 | |||
|
29 | 9 | 16 | 0.27 | 0.31 | 2.6 | 1.07 | 7 | 93 | |||
|
31 | 24 | 14 | 0.28 | 0.32 | 2.1 | 1.11 | 8 | 92 | |||
|
25 | 18 | 14 | 0.21 | 0.24 | 2.1 | 1.19 | 3 | 97 | |||
|
19 | 12 | 14 | 0.19 | 0.21 | 2.1 | 1.00 | 3 | 97 |
Product | Visual Comfort | Thermal Comfort | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
External Reflection (%) | Internal Reflection (%) | Solar Factor (SF/SHGC) |
co-efficient (SC) |
U-value (W/m2K) | Selectivity | Tuv (%) | UV cutdown(%) | |||
|
25 | 29 | 15 | 0.23 | 0.27 | 2 | 1.09 | 7 | 93 | |||
|
21 | 21 | 15 | 0.18 | 0.21 | 2 | 1.17 | 3 | 97 | |||
|
16 | 14 | 15 | 0.16 | 0.19 | 2 | 1.00 | 3 | 97 | |||
|
45 | 15 | 17 | 0.42 | 0.48 | 2.6 | 1.07 | 17 | 83 | |||
|
37 | 12 | 17 | 0.3 | 0.34 | 2.6 | 1.23 | 7 | 93 | |||
|
29 | 9 | 16 | 0.27 | 0.31 | 2.6 | 1.07 | 7 | 93 | |||
|
31 | 24 | 14 | 0.28 | 0.32 | 2.1 | 1.11 | 8 | 92 | |||
|
25 | 18 | 14 | 0.21 | 0.24 | 2.1 | 1.19 | 3 | 97 | |||
|
19 | 12 | 14 | 0.19 | 0.21 | 2.1 | 1.00 | 3 | 97 |